Environmental Monitoring Systems for Server Rooms, Server Racks and Data Centers


Our approach and conceptualization for environmental monitoring over the network is cost-efficient. The solutions offered by us enable you to manage and control the temperature, door contact, dry contact, humidity and some other environmental states distantly from network cabinet to data centers.

Wireless Data Center Monitoring Solutions

Our products provide you automatic and real-time wireless data center supervising methods, which efficiently cut down the expenditure and time of tracking IT assets and manage them.
 
Made-up on open modular, offered solutions can be employed singly or incorporated simply into the active technology substructure— be it is a Building Management Systems (BMS) software, Data Center Infrastructure Management (DCIM), Asset Management, ERP or some other programs.

Features of Wireless Monitoring :-


  • Easy-to-deploy and inexpensive, comes with “peel and stick” wireless detector.
  • Primal admonitory device for humidity, temperature and air pressure problems.
  • Devices for fluid detection, rack level power utilization and more .
  • Adjustable configuration that ensures absolute coverage at low price.
  • Real-time monitoring and warning is offered so as to reduce extra costs, and modifying accessibility.
  • Provisions available from area sized turn-key outfits to larger customized data center floor utilization.

Wire-free data center monitoring provides the key advantages, listed below :-


  • Accessible with reduced overall cost
  • Catchpenny and simple deployment
  • Retains the essential rack space
  • Proffers large scalability as well as future development
  •  

Wireless Monitoring White Papers

The Wire-Free Benefits: Six major profits of Sensor Networks in Data Centers
Best Patterns in the Data Center for the procedure of Wire-free Environmental Monitoring

PDU Environmental Sensors

The deployment of environmental sensors for numerous inline power meters and intelligent rack PDUs, can be done as plug-and-play alternatives. This variety of monitoring doesn't require any separate controller. The environment data is immediately transmitted to the on-board software of PDU. The manageable web-based interface enable the data managers to examine report directions, real-time environment info and assist in fixing the alert commencements.

Environmental sensors allow the data center managers to :-


  • Insure the up-time by using monitoring racks that works for potential hot spots.
  • Reduce the cooling cost by positively increasing the temperatures of data center.
  • Amend the accessibility of data center by obtaining environment alert system.
  • Make strategical conclusions on containment as well as on cooling.
  • Fix alerts and thresholds are there to monitor on-site and distant facilities.

Wired Monitoring Solutions


Smart Rack Controller Monitoring


Smart rack controller monitoring is a fundamental accession point for all of our environmental sensors such as humidity and temperature. This offers asset management, sensor readings and suffices in concurrence with data center infrastructure management solution (DCIM).
Our smart rack controller comes with up to eight feature ports, eight detector ports, for the ever-changing asset-tracking solution. It is also accessible with eight RS-485 ports, with a single 1U form component. Offered rack monitoring solution of ours assists the facilities managers and data center in following ways :

Hold out accurate temperature : It makes the utilization of temperature info to modify the cooling system and increases the temperature of the surrounding so as to save the energy cost and prevent the overheating of erogenous IT equipment.
 
Keeps the humidity under control : Assists in maintaining the humidity levels and obviates the problems related to electrostatic discharge (ESD), which generally occurs due to low humidity. It also solves the condensation difficulties when humidity is at its peak.
 
Maintains the balanced pressure : It can determine air pressure fluctuations, which result in hot and cold aisle structure leaks, and reduce redundant air flow for saving energy.
 
Secures the cabinets : By using a connection closure detector it causes an event; for ex. taking a web-cam image when the cabinet entrance is open.
 
Identifies water leakages : Water leakage from pipes of the water-cooled rack or other outside sources is detectable with this. It also functions with 50% glycol concoction.

Manages and monitors the airflow : Administers the cooling flow rates as well as hot air return so as to insure the optimal functioning of containment and cooling systems.

What To Measure For Data Centers/Server Rooms Monitoring :-


Temperature


The best procedure of environmental monitoring is essentially incorporated with temperature sensors. The arrangement of these should be on top, bottom and middle of the single rack so as to estimate the generated heat. Comely placement of the sensors enable the heat measurement at the air conditioning instrumentality's consumption and discharge holes. The analysis is also important around those critical devices, as the temperature in the interiors of a
rack-mounted device may be more than ambient temperature. The monitoring device near the area's thermostat displays what the thermostat is beholding.

Humidity
High humidity can result in corrosion on electronic parts.
Low humidity levels can effect in static electricity issues.
 
Airflow
It is essential that flowing of air is done via the racks, without disrupting the monitoring of A/C vent consumption and outtakes.

Water
Humidity and moisture sensors should be capable to detect the leaks inside cooling instrumentality. They should be able to identify the potential leaks as well. Water grounded by a flood or catastrophe can be detected by water sensors, which should be arranged at the lowest point on the floor or below any pipe spot. For the detection of overflow, air-conditioning condensation trays should be accoutered with sensors.
 
Voltage
Voltage sensors find out the existence and absence of line voltage. They are also capable of determining the frequency of brown outs so as to insure uninterrupted power supplies.
 
Power
Electrical occurrences can shut down the air-conditioning equipments. The uninterrupted power supply (UPS) guarantees the stay up of servers and prevents the overheating of the server rooms in a shortened order. The best conceptualization is to display current that comes into the data center and set up a systematic shutdown of IT equipment. Maximal two hours of downtime is preferred to the far-flung device occurrences, which yield due to overheating condition.

Smoke
Smoke alarm system can solve out the problem of power shutdowns. They’re not bound to the alert system, which contacts with IT personnel. The provided alarms may be detected by the local fire department or facilities managers. The foremost approach is to wire the smoke alarm system straightaway into the alerting system and climate monitoring, so as to widen the alarm functionality.
 
Doors
Dry-contact sensors notice the opening as well as closing of the doors. They should be set up at the entrance points of the room and UPS cabinets. The sensors are also capable to transmit the alerts many times.

Video Surveillance
In the data center, real-time probe of sensitive regions can bring forth a first-hand aspect, wherever they may be.
 
Power Consumption & Switching
Find out the consumption of power taken by the specific device or power strip.